點(diǎn) 擊 解 答??![]() |
本標(biāo)準(zhǔn)規(guī)定了安裝在垂直分隔構(gòu)件開(kāi)口處的門(mén)和卷簾總成的耐火試驗(yàn)方法。如:——鉸鏈門(mén)、樞軸門(mén);——水平滑動(dòng)門(mén)、垂直滑動(dòng)門(mén),包括鏈接滑動(dòng)門(mén)和分段門(mén);——卷簾門(mén);——其他滑動(dòng)、折疊門(mén);——翻板門(mén);——可在墻中移動(dòng)的門(mén)。本標(biāo)準(zhǔn)規(guī)定的試驗(yàn)方法也可通過(guò)類(lèi)推法用于測(cè)定非承重水平門(mén)和卷簾的耐火性能,第13章中給出的直接應(yīng)用范圍不適用于水平門(mén)。本標(biāo)準(zhǔn)不包括機(jī)械適應(yīng)性方面的要求,例如震動(dòng)試驗(yàn)或耐久試驗(yàn),它們包含在相關(guān)產(chǎn)品標(biāo)準(zhǔn)中。
This part of EN 14511 specifies minimum requirements which ensure that air conditioners, heat pumps and liquidchilling packages with electrical driven compressors are fit for the use designated by the manufacturer when usedfor space heating and/or cooling.This European Standard applies to factory-made units that can be ducted.This standard applies to factory-made liquid chilling packages with integral condensers or for use with remotecondensers.This standard applies to factory-made units of either fixed capacity or variable capacity by any means.Packaged units, single split and multisplit systems are covered by this standard. Single duct and double duct unitsare covered by the standard.In the case of units consisting of several parts, the standard applies only to those designed and supplied as acomplete package, except for liquid chilling packages with remote condenser. OThis standard is primarily intended for water and brine chilling packages but can be used for cooling any otherliquid subject to agreement.This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side.The units having their condenser cooled by air and by the evaporation of external additional water are notcovered by this standard.This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant.Installations used for heating and/or cooling of industrial processes are not within the scope of this standard.NOTE Part load testing of units is dealt with in CEN/TS 14825.
This European Standard covers hinged and pivoted steel (any kind) and aluminium based framed, glazed doorsets or openable windows. This document includes Amendment 1 approved by CEN on 2016-03-13. This European Standard prescribes the methodology for extending the application of test results obtainedfrom resistance to fire test(s) conducted in accordance with EN 1634-1.Subject to the completion of the appropriate test or tests selected from those identified in Clause 4 the extended application may cover all or some of the following examples: - integrity (E), integrity/radiation (EW) or integrity/insulation (EI1 or EI2) classifications; - doorsets and openable windows; - door / window leaf (leaves); - glazing and non-glazed panels in doorset and openable window; - items of building hardware; - decorative finishes; - intumescent, smoke, draught or acoustic seals; - alternative supporting construction(s).
This European guidance document provides guidance on the selection of existing building hardware for manually and power operated pedestrian doors and associated products whose integration into the design of buildings will make them more safe, secure and convenient for the occupants inclusive of children, elderly and disabled people to use (\"design for all\"). Although it is intended for people with reduced physical and sensorial capabilities, it may not cover all specific individual needs. For example, it may not cover all needs of blind people or those not able to move unassisted.
This European Standard specifies requirements, methods of test and performance criteria against which thecompatibility of components and their performance can be assessed when used in combination to form anelectrically controlled hold-open system. It also specifies requirements for the integrity of such hold-opensystems when connected to fire detection and fire alarm systems or other systems, including the signalexchange and technical data for interfaces.This European Standard provides requirements for the application of electrically controlled hold-open systemsused for fire/smoke doors in buildings, where such doors are required to be self-closing. It covers planning,design (see Annex A), installation (see Annex B), commissioning, use and maintenance (see Annex E) ofhold-open systems, intended for the protection of life and/or the protection of property. This may also includehold-open systems, or components of the hold-open system, that are self-contained in a single enclosure.Electrically controlled hold-open systems manufactured, installed and serviced in accordance with thisEuropean Standard are recommended for use wherever there is a requirement for reliable hold-open andrelease of an individual self-closing fire/smoke door assembly in the case of fire.The use of hold-open systems for closures in conveyor systems conforming to EN 1366-7, which applies inconjunction with EN 1363-1, may require additional proof of suitability, which is not covered by this EuropeanStandard.This European Standard does not cover design, installation, commissioning, use and maintenance of buildingfire detection and fire alarm systems (covered by CEN/TS 54-14) but does cover the connection of hold-opensystems conforming to this European Standard to building fire detection and fire alarm systems, under certainprescribed conditions.This European Standard does not cover the requirements of performance characteristics and operationalenvironment conditions of particular components of a hold-open system, where these requirements arealready covered by European specifications, and which include appropriate test methods to assurereproducible test results for the product conformity assessment. These European Standards are referred to inClause 5.This European Standard does not cover electrically controlled systems used for smoke venting purposes orsystems that allow the door to remain open under fault conditions (i.e. not fail-safe).This European Standard does not cover electrically controlled hold-open systems that are not connected tomain power supply and are battery powered only.