本部分適用于小額定表壓力為-69kPa、大額定表壓力為4.2MPa的壓力敏感電自動控制器,它們是在家用和類似用途設(shè)備上、設(shè)備內(nèi)或附在設(shè)備上使用的,也包括加熱、空調(diào)和類似的應(yīng)用,這些設(shè)備可以是使用電、燃?xì)?、油、固體燃料、太陽能等或它們的組合能源。
本標(biāo)準(zhǔn)規(guī)定了使用GB/T 13611規(guī)定的城鎮(zhèn)燃?xì)獾娜細(xì)馊紵骱腿紵骶哂冒踩涂刂蒲b置及其組件(以下簡稱“控制裝置”)的術(shù)語和定義、分類和分組、結(jié)構(gòu)和材料、要求、試驗方法、標(biāo)識、安裝和操作說明書、包裝、運輸和貯存。本標(biāo)準(zhǔn)適用于以下控制裝置:--自動和半自動閥;--燃燒控制裝置;--熄火保護裝置;--燃?xì)夂涂諝獗壤{(diào)節(jié)裝置;--壓力調(diào)節(jié)裝置;--旋塞閥總成;--溫度控制裝置;--多功能控制裝置;--壓力傳感裝置;--閥門檢驗系統(tǒng)。
本標(biāo)準(zhǔn)規(guī)定了燃?xì)馊紵骶吲欧盼镏蠳O<下標(biāo)x>、CO、CO<下標(biāo)2>和O<下標(biāo)2>測定的術(shù)語和定義,測量系統(tǒng)、分析儀、輔助設(shè)備和附件,系統(tǒng)檢驗,取樣,測試操作,計算方法。本標(biāo)準(zhǔn)適用于燃?xì)馊紵骶叩男褪綑z驗及其他檢驗中排放物的測定。
本標(biāo)準(zhǔn)規(guī)定了房間空氣調(diào)節(jié)器室外機安裝用支架的、要求、試驗方法、標(biāo)志、包裝、運輸和貯存。本標(biāo)準(zhǔn)適用于房間空氣調(diào)節(jié)器(額定制冷量14 000 W以下)室外機安裝用支架。
本標(biāo)準(zhǔn)規(guī)定了瓶裝液化石油氣調(diào)壓器(以下簡稱調(diào)壓器)的分類和型號、要求、試驗方法、檢驗規(guī)則,標(biāo)志、警示和使用說明書,包裝、運輸和貯存。本標(biāo)準(zhǔn)適用于進(jìn)口壓力為0.03 MPa~1.56 MPa,額定出口壓力為2.80 kPa,額定流量小于或等于2 m<上標(biāo)3>/h,使用環(huán)境溫度為-20 ℃~+45 ℃的家用瓶裝液化石油氣調(diào)壓器(以下簡稱家用調(diào)壓器);以及進(jìn)口壓力為0.03 MPa~1.56 MPa,額定出口壓力為2.80 kPa或5.00 kPa,額定流量小于或等于3.6 m<上標(biāo)3>/h,使用環(huán)境溫度為-20 ℃~+45 ℃的商用瓶裝液化石油氣調(diào)壓器(以下簡稱商用調(diào)壓器)。本標(biāo)準(zhǔn)所提到的壓力值凡未標(biāo)注的均指表壓。
本標(biāo)準(zhǔn)規(guī)定了使用GB/T 13611規(guī)定的城鎮(zhèn)燃?xì)獾娜紵骱腿紵骶哂米詣雍桶胱詣娱y(以下簡稱閥門)的術(shù)語和定義,分類和分組,結(jié)構(gòu)和材料,要求,試驗方法,檢驗規(guī)則,標(biāo)志、安裝和操作說明書,包裝、運輸和貯存。本標(biāo)準(zhǔn)適用于大進(jìn)口壓力不大于500 kPa,用于燃?xì)鉄崴?、燃?xì)獠膳療崴疇t、燃?xì)馊紵?機、燃?xì)馊∨?、燃?xì)庹粝?、燃?xì)忮仩t等燃?xì)馊紵骶呋蛉紵O(shè)備,以電磁、電動或以機械方式直接或間接操作啟閉的常閉閥門。本標(biāo)準(zhǔn)不適用于CJ/T 132規(guī)定的閥門。
本規(guī)范適用于向城市、鄉(xiāng)鎮(zhèn)和居民點供給居民生活、商業(yè)、工業(yè)企業(yè)生產(chǎn)等各類用戶作燃料用的新建、改建人工制氣廠站工程設(shè)計。
本標(biāo)準(zhǔn)規(guī)定了以城鎮(zhèn)燃?xì)鉃槿剂系闹胁腿細(xì)獬床嗽畹男g(shù)語和定義、分類和型號,結(jié)構(gòu)和材料,要求,試驗方法,檢驗規(guī)則,標(biāo)識、警示和使用說明書以及包裝、運輸和貯存。本標(biāo)準(zhǔn)適用于每個燃燒器額定熱負(fù)荷不大于60kW的中餐燃?xì)獬床嗽睿ㄒ韵潞喎Q炒菜灶)。本標(biāo)準(zhǔn)所指城鎮(zhèn)燃?xì)鉃榉螱B/T 13611的燃?xì)狻?/p>
本標(biāo)準(zhǔn)規(guī)定了熱電式燃具熄火保護裝置(以下簡稱“熄火保護裝置”)的術(shù)語和定義、分類、結(jié)構(gòu)和材料、要求、試驗方法、檢驗規(guī)則、標(biāo)識、安裝和操作說明書、包裝、運輸和貯存。本標(biāo)準(zhǔn)適用于標(biāo)明大工作壓力在10 kPa以下,公稱連接尺寸不大于DN50,并使用符合GB/T 13611規(guī)定的城鎮(zhèn)燃?xì)馄骶呱嫌脽犭娛饺季呦ɑ鸨Wo裝置。本標(biāo)準(zhǔn)也適用于:--由熱電勢驅(qū)動的、能被單獨測試的、用于熱電式燃具熄火保護裝置的電磁閥;--火焰?zhèn)鞲杏玫臒犭娕?--使用輔助能的熱電式燃具熄火保護裝置(例如外部提供的電能)。
本標(biāo)準(zhǔn)規(guī)定了家用燃?xì)馊紵骶哂米晕y(以下簡稱自吸閥)的術(shù)語和定義、分類和分組、結(jié)構(gòu)和材料、要求、試驗方法、標(biāo)識、安裝和操作說明書、檢驗規(guī)則、包裝、運輸和貯存。本標(biāo)準(zhǔn)適用于大工作壓力不大于10 kPa,公稱尺寸不大于DN32,工作電壓不大于DC 6V,僅以電池驅(qū)動的,使用GB/T 13611規(guī)定的城鎮(zhèn)燃?xì)馄骶哂米晕y。
本標(biāo)準(zhǔn)規(guī)定了以城鎮(zhèn)燃?xì)鉃槿剂系娜細(xì)庹粝涞男g(shù)語和定義,分類和型號,結(jié)構(gòu)和材料,要求,試驗方法,檢驗規(guī)則,標(biāo)識,警示和使用說明書以及包裝、運輸和貯存。本標(biāo)準(zhǔn)適用于額定熱負(fù)荷不大于80kW、蒸腔蒸汽壓力不大于500Pa(表壓)的燃起蒸箱(以下簡稱蒸箱)。本標(biāo)準(zhǔn)所指城鎮(zhèn)燃?xì)鉃榉螱B/T 13611的燃?xì)狻?/p>
本標(biāo)準(zhǔn)規(guī)定了加熱生活用水的冷凝式家用燃?xì)饪焖贌崴鞯姆诸惡托吞枴⒉牧虾徒Y(jié)構(gòu)、要求、試驗方法、驗收規(guī)則及標(biāo)志和說明書、包裝、運輸和貯存。本標(biāo)準(zhǔn)適用于除人工煤氣之外符合GB/T 13611規(guī)定燃?xì)?、額定熱輸入不大于70kW的強制排氣式冷凝熱水器、強制給排氣式冷凝熱水器和室外型冷凝熱水器。
本標(biāo)準(zhǔn)規(guī)定了家用燃具自動截止閥的術(shù)語和定義、分類、結(jié)構(gòu)和材料、要求、試驗方法、標(biāo)識、安裝和操作說明書、檢驗規(guī)則、包裝、運輸和貯運。本標(biāo)準(zhǔn)適用于標(biāo)明大工作壓力在10kPa以下,公稱直徑不大于DN50,并且使用GB/T 13611規(guī)定的城鎮(zhèn)燃?xì)獾钠骶呱系拈y門。本標(biāo)準(zhǔn)適用于以電磁、電動或以機械方式直接或間接操作的閥門。本標(biāo)準(zhǔn)適用于流體驅(qū)動控制閥(流體如:氣體、液體)。本標(biāo)準(zhǔn)適用于裝有關(guān)閉位置指示開關(guān)的閥門。
本標(biāo)準(zhǔn)規(guī)定了燃?xì)馊紵骱腿細(xì)馊紵骶哂脷鈩邮饺細(xì)?空氣比例調(diào)節(jié)裝置(以下簡稱“比例調(diào)節(jié)裝置”)的術(shù)語和定義、分類和分組、結(jié)構(gòu)和材料、要求、試驗方法、檢驗規(guī)則、標(biāo)識、安裝和操作說明書以及包裝、運輸和貯存。本標(biāo)準(zhǔn)適用于標(biāo)明大工作壓力不大于50 kPa,公稱尺寸不大于DN250,使用GB/T 13611規(guī)定的城鎮(zhèn)燃?xì)?由空氣壓力改變?nèi)細(xì)鈮毫η夷軌騿为殰y試的比例調(diào)節(jié)裝置。由燃?xì)鈮毫Ω淖兛諝鈮毫Φ谋壤{(diào)節(jié)裝置可參考本標(biāo)準(zhǔn)執(zhí)行。本標(biāo)準(zhǔn)不適用于機械聯(lián)動的比例調(diào)節(jié)裝置和電子控制的比例調(diào)節(jié)裝置。
Le présent document fixe des règles de calcul pour :- dimensionner des canalisations d'alimentation en gaz combustibles et en hydrocarbures liquéfiés des appareils installés dans les batiments d'habitation et de leurs dépendances,- dimensionner des systèmes d'évacuation des produits de combustion fonctionnant en tirage naturel des appareils de types B1 et B2 de débit calorifique nominal inférieur ou égal à 85 kW,- dimensionner les systèmes d'évacuation des produits de combustion des appareils installés en alvéoles techniques gaz,- déterminer le nombre admissible d'appareils de type C dont les terminaux débouchent dans les courettes fermées et les configurations en U.Les prescriptions applicables à ces différents cas sont présentées en Annexes A, B et C. Ces Annexes précisent également leur domaine d'application particulier respectif.
This European standard specifies the characteristics of safety, construction, performance and efficiency, the test methods and marking, of room sealed space heating equipment of types C(see CEN/TR 1749)with combustion air intake and outlet for the products of combustion in the wall, roof of floor,combined or not.
This European Standard specifies the requirements and test methods for the construction, safety and marking of domestic direct gas-fired tumble dryers, of types B22D and B23D, of nominal heat input not exceeding 6 kW, hereafter referred to as \"appliances\". This European Standard does not apply to: a) catalytic combustion appliances; b) appliances designed exclusively for industrial purposes; c) appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere; d) appliances of the condensing type wherein the heated air and products of combustion used for the drying process are dehumidified by cooling with water or air; e) appliances intended to be used in vehicles or on board ships or aircraft. This European Standard covers type testing only.
This European Standard specifies functional requirements for the design, construction, testing, commissioning/decommissioning, operation, maintenance and, where appropriate, calibration, together with suitable documented provisions for all new gas measuring systems and any major changes of existing systems. This European Standard also specifies accuracy classes of measuring systems and thresholds applicable to these classes. Demonstration of compliance is achieved through the selection, installation and operation of appropriate measurement instruments, together with suitable documented provisions for calculations. Examples of demonstration of compliance are provided for each accuracy class; however, they are not prescriptive solutions. This European Standard is applicable for gases of the 2nd family as classified in EN 437. It is also applicable for treated non-conventional combustible gases complying with EN 437 and for which a detailed technical evaluation of the functional requirements (such as injected biomethane) is performed ensuring there are no other constituents or properties of the gases that can affect the metrological and physical integrity of the measuring systems. This European Standard can also be used as a guideline for 1st and 3rd family gases as classified in EN 437; however additional considerations should be taken with regard to the different constituents and physical characteristics of the gas family. This European Standard gives guidelines when designing, installing and operating gas meters with additional functionalities (smart gas meters). Communication protocols and interfaces for gas meters and remote reading of gas meters are outside the scope of this European Standard and are covered by the appropriate parts of EN 13757, which provide a number of protocols for meter communications. Supervisory control and data acquisition protocols (SCADA) are also not covered by this European Standard. Unless otherwise specified all pressures used in thi
The objective of this European Standard is to achieve the safe operation of gas connection valves for use with metal hose assemblies by specifying the requirements of performance, materials and test methods. Metal hose assemblies are referred to in prEN 14800 and prEN 15070. These valves are suitable for connection to domestic appliances inside or outside a dwelling using gas at a pressure of up to and including 0,5 bar. These valves are designed for the use with movable appliances; they may also be used for the connection of fixed appliances. The term gas relates to the first, second and third families as referred to in EN 437,Table 1.
This part of BS 5440 specifies requirements for the installation of gasappliances to chimneys, chimney installation work likely to beundertaken by gas engineers and operatives working under UK gasindustry conditions and requirements for the maintenance of chimneys.It is applicable to open flue chimneys for Type B gas appliances androom-sealed chimney configurations for Type C gas appliances, each ofrated input not exceeding 70 kW net (see Note 2 and Note 3), burning1st, 2nd or 3rd family gases. It applies to chimneys of the naturaldraught or fanned draught type and is applicable to open flue chimneysand room-sealed chimneys supplied with the appliance as well as tothose supplied separately.It complements the requirements for the design, installation andcommissioning of chimneys as required in BS EN 15287-1 andBS EN 15287-2 and requires extra details that are specific to the UK gasindustry. This is kept in perspective by quoting some details ofBS EN 15287-1 and BS EN 15287-2.It specifies the following:? requirements for the selection of the appropriate flueing option forgas appliances in the UK;? requirements for the installation of gas appliances to newchimneys, or chimney configurations;? requirements for the installation of gas appliances to existingchimneys or chimney configurations;? requirements for the installation of appliances which carry a CEmark and for which the manufacturer’s instructions are availableto the installer;? requirements installation of appliances which do not carry a CEmark and used/second-hand appliances for which themanufacturer’s instructions are available to the installer.This part of BS 5440 is applicable to:? complete chimney and all chimney components from the applianceconnection to the discharge point into outside air;? the installation of gas appliances to existing chimneys that wereintended originally for appliances burning other fuels;? chimneys for residential park homes but not to chimneys forleisure accommodation vehicles.This part of BS 5440 is not applicable to gas-fired incinerators. Refer toBS 5871-3 for the installation of decorative fuel effect appliances.This part of BS 5440 includes compatibility of appliances installed inthe UK with new chimneys designated under BS EN 1443 and withexisting chimneys, including non-designated chimneys.