點(diǎn) 擊 解 答??![]() |
本標(biāo)準(zhǔn)規(guī)定了模擬抗風(fēng)揭拉拔測(cè)試方法、靜態(tài)正壓或負(fù)壓抗風(fēng)揭測(cè)試方法和動(dòng)態(tài)負(fù)壓抗風(fēng)揭測(cè)試方法三種測(cè)試單層卷材屋面系統(tǒng)抗風(fēng)揭性能的試驗(yàn)方法。本標(biāo)準(zhǔn)適用于采用機(jī)械固定或滿(mǎn)粘施工的單層卷材屋面系統(tǒng)。
本標(biāo)準(zhǔn)規(guī)定了建筑幕墻的通用術(shù)語(yǔ)和定義。本標(biāo)準(zhǔn)適用于各種類(lèi)型的建筑幕墻。
GB/T 37260的本部分規(guī)定了可拆裝式箱型輕鋼結(jié)構(gòu)房屋的術(shù)語(yǔ)和定義、規(guī)格和標(biāo)記、一般要求、材料及構(gòu)件、工藝及性能、試驗(yàn)方法、檢驗(yàn)規(guī)則以及標(biāo)志、包裝、運(yùn)輸和貯存。本部分適用于具有建筑使用功能,可獨(dú)立使用的或作為一個(gè)建筑體組合模塊的可拆裝式箱型輕鋼結(jié)構(gòu)房屋。
本規(guī)程適用于新建、擴(kuò)建、改建的游泳池及類(lèi)似水環(huán)境水池的給水排水工程的設(shè)計(jì)、施工、檢測(cè)、調(diào)試、驗(yàn)收、運(yùn)行、維護(hù)和管理。
本標(biāo)準(zhǔn)規(guī)定了輕質(zhì)混凝土吸聲板的術(shù)語(yǔ)和定義、分類(lèi)、規(guī)格尺寸和標(biāo)記、一般規(guī)定、技術(shù)要求、試驗(yàn)方法、檢驗(yàn)規(guī)則以及標(biāo)志、包裝、運(yùn)輸和貯存等。本標(biāo)準(zhǔn)適用于以水泥為膠凝材料,以輕集料為集料,加入水和外加劑,經(jīng)攪拌、入模成型、養(yǎng)護(hù)制成的具有吸聲功能的制品,可用于建筑、公路、鐵路、市政等工程。
本標(biāo)準(zhǔn)規(guī)定了輕型木結(jié)構(gòu)建筑覆面板用定向刨花板的術(shù)語(yǔ)和定義、分類(lèi)、要求、試驗(yàn)方法、抽樣方法及判定規(guī)則、工廠質(zhì)量控制、標(biāo)識(shí)、包裝、運(yùn)輸和貯存等。本標(biāo)準(zhǔn)適用于輕型木結(jié)構(gòu)建筑覆面板用的定向刨花板,包括用作屋面板、墻面板和樓面板的定向刨花板。本標(biāo)準(zhǔn)涉及的定向刨花板其膠合等級(jí)為暴露I級(jí)。
本標(biāo)準(zhǔn)規(guī)定了建筑結(jié)構(gòu)保溫復(fù)合板的術(shù)語(yǔ)和定義、分類(lèi)和標(biāo)記、材料、要求、試驗(yàn)方法、檢驗(yàn)規(guī)則、標(biāo)志及包裝、運(yùn)輸與貯運(yùn)等。本標(biāo)準(zhǔn)適用于建筑非承重圍護(hù)結(jié)構(gòu)用保溫復(fù)合墻板。
本規(guī)程適用于10層及10層以上或房屋高度大于28m的住宅建筑以及房屋高度大于24m的其他高層民用建筑混凝土結(jié)構(gòu)。非抗震設(shè)計(jì)和抗震設(shè)防烈度為6至9度抗震設(shè)計(jì)的高層民用建筑結(jié)構(gòu),其適用的房屋大高度和結(jié)構(gòu)類(lèi)型應(yīng)符合本規(guī)程的有關(guān)規(guī)定。本規(guī)程不適用于建造在危險(xiǎn)地段以及發(fā)生震斷裂小避讓距離內(nèi)的高層建筑結(jié)構(gòu)。
本規(guī)程適用于以輕型鋼框架為結(jié)構(gòu)體系,并配套有滿(mǎn)足功能要求的輕質(zhì)墻體、輕質(zhì)樓板和輕質(zhì)屋面建筑系統(tǒng),層數(shù)不超過(guò)6層的非抗震設(shè)防以及抗震設(shè)防烈度為6~8度的輕型鋼結(jié)構(gòu)住宅的設(shè)計(jì)、施工及驗(yàn)收。
本標(biāo)準(zhǔn)適用于新建、改建和擴(kuò)建民用建筑的綠色設(shè)計(jì)。
本規(guī)程適用于8層及8層以下且房屋高度不超過(guò)24m的多層密肋復(fù)合板結(jié)構(gòu)及9層及9層以上或房屋高度超過(guò)24m的高層密肋復(fù)合板結(jié)構(gòu)。非抗震設(shè)計(jì)和抗震設(shè)防烈度為6度至8度抗震設(shè)計(jì)的密肋復(fù)合板結(jié)構(gòu),其適用的房屋大高度應(yīng)符合本規(guī)程的有關(guān)規(guī)定。本規(guī)程不適用于建造在危險(xiǎn)地段以及發(fā)震斷裂小避讓距離內(nèi)的密肋復(fù)合板結(jié)構(gòu)。
本規(guī)范適用于住宅的室內(nèi)裝飾裝修設(shè)計(jì),不適用屬于歷史文物保護(hù)的住宅的室內(nèi)裝飾裝修設(shè)計(jì)。
本標(biāo)準(zhǔn)適用于采用裝配式建筑結(jié)構(gòu)體與建筑內(nèi)裝體集成化建造的新建、改建和擴(kuò)建住宅建筑設(shè)計(jì)。
This practice is used to outline the minimum necessary elements and conditions to obtain an accurate determination of the location of wet insulation in roofing systems using infrared imaging. This practice is not meant to be an instructional document or to provide all the knowledge and background necessary to provide an accurate analysis. For further information, see ANSI-ASHRAE Standard 101 and ISO/DP 6781.3E. This practice does not provide methods to determine the cause of moisture or its point of entry. It does not address the suitability of any particular system to function capably as waterproofing.1.1 This practice applies to techniques that employ infrared imaging at night to determine the location of wet insulation in roofing systems that have insulation above the deck in contact with the waterproofing. This practice includes ground-based and aerial inspections. (Warning8212;Extreme caution shall be taken when accessing or walking on roof surfaces and when operating aircraft at low altitudes, especially at night.) (Warning8212;It is a good safety practice for at least two people to be present on the roof surface at all times when ground-based inspections are being conducted.) 1.2 This practice addresses criteria for infrared equipment such as minimum resolvable temperature difference, spectral range, instantaneous field of view, and field of view. 1.3 This practice addresses meteorological conditions under which infrared inspections shall be performed. 1.4 This practice addresses the effect of roof construction, material differences, and roof conditions on infrared inspections. 1.5 This practice addresses operating procedures, operator qualifications, and operating practices. 1.6 This practice also addresses verification of infrared data using invasive test methods. 1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 1.1.
P Eurocode 2 applies to the design of buildings and civil engineering works in plain, reinforced and prestressed concrete. It complies with the principles and requirements for the safety and serviceability of structures, the basis of their design and verification that are given in EN 1990: Basis of structural design.
This European Standard describes the method of specifying the design, installation criteria for system chimneys, construction of custom built chimneys, and the relining of existing chimneys. It also gives information on commissioning of chimneys.This European Standard also deals with connecting flue pipes.This European Standard does not apply to freestanding chimneys covered by EN 13084-1.This European Standard excludes chimneys designated H (high positive pressure chimneys) and chimneys for room-sealed heating appliances. For the purpose of this European Standard the term \"installation\" includes construction.
This document contains catagorized results of fire tests of buildings materials, components and construction types. Due to the assignment to the classes of building materials according to DIN 4102 part 1 and the fire resistance classes of the other parts of DIN 4102 respectively, further fire tests for the verification of usability required by the building regulations are not necessary.