亚洲精品一区二区久,亚洲欧美精品综合在线观看,一区,二区,三区色视频,中国黄色片毛,免费,中国熟妇videosexfreexxxx片

歡迎訪問中科光析科學(xué)技術(shù)研究所官網(wǎng)!

您的位置:首頁 > 其他

金屬面硬質(zhì)酚醛泡沫復(fù)合板檢測(cè)

發(fā)布日期: 2024-06-21 17:34:53 - 更新時(shí)間:2024年06月29日 15:22

金屬面硬質(zhì)酚醛泡沫復(fù)合板檢測(cè)項(xiàng)目報(bào)價(jià)???解決方案???檢測(cè)周期???樣品要求?

點(diǎn) 擊 解 答??

GB 50693-2011坡屋面工程技術(shù)規(guī)范

為提高我國(guó)坡屋面工程技術(shù)水平,確保工程質(zhì)量,制定本規(guī)范。本規(guī)范適用于新建、擴(kuò)建和改建的工業(yè)建筑、民用建筑坡屋面工程的設(shè)計(jì)、施工和質(zhì)量驗(yàn)收。坡屋面工程的設(shè)計(jì)和施工應(yīng)遵守有關(guān)環(huán)境保護(hù)、建筑節(jié)能和安全的規(guī)定,并應(yīng)采取相應(yīng)措施。 坡屋面工程應(yīng)積極采用成熟的新材料、新技術(shù)、新工藝。坡屋面工程的設(shè)計(jì)、施工和質(zhì)量驗(yàn)收除應(yīng)符合本規(guī)范外,尚應(yīng)符合現(xiàn)行有關(guān)標(biāo)準(zhǔn)的規(guī)定。

CECS 411-2015金屬面絕熱夾芯板技術(shù)規(guī)程

本規(guī)程適用于工業(yè)與民用建筑屋面板(非上人屋面)、墻面板、天花板、內(nèi)隔墻、聲屏障等的設(shè)計(jì)及安裝。

CECS 445-2016非金屬面結(jié)構(gòu)保溫夾芯板設(shè)計(jì)規(guī)程

本規(guī)程適用于工業(yè)與民用建筑采用的圍護(hù)結(jié)構(gòu)、輕型屋面、吊頂板等用的非金屬面結(jié)構(gòu)保溫夾芯板的設(shè)計(jì)。

JC/T 1051-2018金屬面硬質(zhì)酣醛泡沫復(fù)合板

本標(biāo)準(zhǔn)規(guī)定了金屬面硬質(zhì)酚醛泡沫復(fù)合板產(chǎn)品的術(shù)語和定義、分類和標(biāo)記、金屬面層材料、技術(shù)要求、試驗(yàn)方法、檢驗(yàn)規(guī)則以及標(biāo)志、包裝、運(yùn)輸和貯存。本標(biāo)準(zhǔn)適用于工業(yè)與民用建筑通風(fēng)、空調(diào)系統(tǒng)風(fēng)管用金屬面硬質(zhì)酚醛泡沫復(fù)合板。

JC/T 2155-2012建筑用金屬面酚醛泡沫夾芯板

本標(biāo)準(zhǔn)規(guī)定了建筑用金屬面酚醛泡沫夾芯板產(chǎn)品的術(shù)語和定義、分類和標(biāo)記、原材料、要求、試驗(yàn)方法、檢驗(yàn)規(guī)則以及包裝、運(yùn)輸和貯存等。本標(biāo)準(zhǔn)適用于以彩色涂層鋼板為面層工廠化生產(chǎn)的工業(yè)與民用建筑外墻、隔墻、屋面、天花板的酚醛泡沫夾芯板。其他用途時(shí)可參照本標(biāo)準(zhǔn)執(zhí)行。

JG/T 432-2014建筑結(jié)構(gòu)保溫復(fù)合板

本標(biāo)準(zhǔn)規(guī)定了建筑結(jié)構(gòu)保溫復(fù)合板的術(shù)語和定義、分類和標(biāo)記、材料、要求、試驗(yàn)方法、檢驗(yàn)規(guī)則、標(biāo)志及包裝、運(yùn)輸與貯運(yùn)等。本標(biāo)準(zhǔn)適用于建筑非承重圍護(hù)結(jié)構(gòu)用保溫復(fù)合墻板。

JGJ/T 350-2015保溫防火復(fù)合板應(yīng)用技術(shù)規(guī)程

本規(guī)程適用于新建、擴(kuò)建和改建的民用建筑中采用保溫防火復(fù)合板的外墻外保溫工程的設(shè)計(jì)、施工及質(zhì)量驗(yàn)收。

DIN EN 13162-2015建筑物隔熱產(chǎn)品.工廠制礦棉(MW)制品.規(guī)格.德文版本EN 13162-2012+A1-2015

This European Standard specifies the requirements for factory made mineral wool products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the mat blankets, boards or slabs.Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.Products with a declared thermal resistance lower than 0,25 m2 K/W or a declared thermal conductivity greater than 0,060 W/(m·K) at 10 °C are not covered by this standard. This standard does not cover in situ insulation products (covered by EN 14064 parts 1 and 2) and products intended to be used for the insulation of building equipment and industrial installations (covered by EN 14303).

DIN EN 13164-2015建筑用隔熱產(chǎn)品.工廠制聚苯乙烯泡沫(XPS)產(chǎn)品.規(guī)格.德文版本EN 13164-2012+A1-2015

This European Standard specifies the requirements for factory made products of extruded polystyrene foam, with or without facings or coatings, which are used for thermal insulation of buildings. The products are manufactured in the form of boards, which are also available with special edge and surface treatment (tongue & grooves, shiplap etc.). This standard includes XPS multi-layered insulation boards with layers perpendicular to the edges of the board, i.e. layers parallel to the surface of the final board.Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.The standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.Products with a declared thermal resistance lower than 0,25 m2 K/W or a declared thermal conductivity greater than 0,060 W/(m·K) at 10 °C are not covered by this standard.This standard does not cover in situ insulation products, nor products intended to be used for the insulation of building equipment and industrial installations, or civil engineering applications or acoustic insulation.

DIN EN 13166-2016建筑物隔熱產(chǎn)品.酚醛泡沫的工廠制(PF) 產(chǎn)品.規(guī)格.德文版本EN 13166-2012+A2-2016

This European Standard specifies the requirements for factory made phenolic foam products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards and laminates. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. Products with a declared thermal resistance lower than 0,40 m2K/W or a declared thermal conductivity greater than 0,050 W/(mK) at 10 °C are not covered by this standard. This standard does not cover in-situ thermal insulation products, products intended to be used for the thermal insulation of building equipment and industrial installations (covered by EN 14314 (3)).

DIN EN 13167-2015建筑物隔熱產(chǎn)品.工廠制泡沫玻璃(CG)產(chǎn)品.規(guī)格;德文版本EN 13167-2012+A1-2015

This European Standard specifies the requirements for factory made cellular glass (CG) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.This standard includes CG multi-layered insulation products. Instructions of Annex C shall be followed.Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards.Products with a declared thermal resistance lower than 0,50 m2 K/W or a declared thermal conductivity greater than 0,065 W/(m·K) at 10 °C are not covered by this standard.This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

DIN EN 13168-2015建筑物用熱隔絕產(chǎn)品.工廠制木絲(WW)產(chǎn)品.規(guī)格.德文版本EN 13168-2012+A1-2015

This European Standard specifies the requirements for factory made wood wool (WW) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards or slabs.This European Standard also specifies the requirements for the factory made composite products, made from wood wool in combination with other insulation materials. This standard includes WW multilayered insulation products. Instructions of annex C shall be followed. This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.Products covered by this European Standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels and classes required for a given application are to be found in regulations or non conflicting standards.Products with a declared thermal resistance lower than 0,15 m2 K/W or a declared thermal conductivity greater than 0,100 W/(m·K) at 10 °C are not covered by this standard.This European Standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

DIN EN 13169-2015建筑物用隔熱產(chǎn)品.工廠制膨脹珍珠巖(EPB)產(chǎn)品.規(guī)格.德文版本EN 13169-2012+A1-2015

This European standard specifies the requirements for factory made expanded perlite board (EPB) products, with or without facings or coatings, which are used for the thermal insulation of buildings. The products are manufactured in the form of boards, multi layered insulation or composite insulation products.This standard includes EPB multi-layered insulation products. Instructions of Annex D shall be followed.This standard also covers composite insulation products (see Annex E).Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered.This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non conflicting standards.Products with a declared thermal resistance lower than 0,15 m2 K/W or a declared thermal conductivity greater than 0,070 W/(m·K) at 10 °C are not covered by this standard.This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations. This standard does not cover the following acoustical aspects: acoustic absorption index and direct airborne sound insulation.

DIN EN 13171-2015建筑物用隔熱產(chǎn)品.工廠制木纖維(WF)產(chǎn)品.規(guī)格.德文版本EN 13171-2012+A1-2015

This European Standard specifies the requirements for factory made wood fibre (WF) products, with or without facings or coatings, which are used for the thermal insulation of buildings ). The products are manufactured in the form of rolls, batts, felts, boards or slabs.This standard includes WF multi-layered insulation products. Instructions of Annex C shall be followed.Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered.This standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The classes and levels required for a given application are to be found in regulations or non-conflicting standards.Products with a declared thermal resistance lower than 0,20 m2 K/W or a declared thermal conductivity greater than 0,070 W/(m·K) at 10 °C are not covered by this standard.This standard does not cover in situ insulation products and products intended to be used for the insulation of building equipment and industrial installations.

DIN EN 13950-2014隔熱/隔音石膏復(fù)合板.定義、要求和試驗(yàn)辦法.德文版本EN 13950-2014

This European Standard specifies the characteristics and performance of thermal/acoustic insulation composite panels made of an insulating material laminated to gypsum boards for which the main intended use is the internal insulation (thermal and/or acoustic) of walls. They are attached with adhesives or by mechanical fixings to vertical solid backgrounds and by mechanical fixings to wood or metal framing with the gypsum board face exposed. The method of fixing and jointing should ensure that the insulating material is not exposed in its normal application. This European Standard covers the following performance characteristics: reaction to fire, fire resistance, water vapour permeability, flexural strength, impact resistance, direct airborne sound insulation and thermal resistance to be measured according to the corresponding European test methods. It provides for the assessment and verification of constancy of performance of the products to this European Standard. This European Standard covers also additional technical characteristics that are of importance for the use and acceptance of the product by the construction industry.

DIN EN 14303-2016建筑設(shè)備和工業(yè)裝置用隔熱產(chǎn)品.工廠制礦物棉(MW)產(chǎn)品.規(guī)范;德文版本EN 14303-2015

for the thermal insulation of building equipment and industrial installations with an operating temperature range of approximately 0 °C to + 800 °C. Below an operating temperature of ambient, special means against water vapour diffusion and water accumulation by air flow might be required. Below an operating temperature of - 50 °C, special tests regarding the suitability of the products in the intended application are advised (e. g. liquefaction of oxygen). Manufacturer's advice should be heeded in all cases. The products are manufactured with or without facings or coatings, in the form of rolls, boards, slabs, mats, felts, quilts, wired mats, lamella mats, bevelled lags and pipe sections. This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property that should be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender. Products with a declared thermal conductivity greater than 0,065 W/(m·K) at 10 °C are not covered by this standard. This European Standard does not cover products for in situ insulation (blowing or pouring) or products for the insulation of the building structure. This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission index.

DIN EN 14305-2016建筑設(shè)備和工業(yè)裝置用保溫制品.工廠預(yù)制泡沫玻璃(CG)制品.規(guī)范.德文版本EN 14305-2015

This European Standard specifies the requirements for factory made cellular glass products which are used for the thermal insulation of building equipment and industrial installations with an operating temperature range of approximately - 265 °C to + 430 °C. Below an operating temperature of - 50 °C, special tests regarding the suitability of the product in the intended application are advised (e. g. liquefaction of oxygen). Manufacturer's advice should be heeded in all cases. The products are manufactured in the form of faced or unfaced boards, pipe sections, segments and prefabricated ware. This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this standard are also used in prefabricated thermal insulation systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property that should be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender. Products with a declared thermal conductivity greater than 0,065 W/(m·K) at 10 °C are not covered by this standard. This European Standard does not cover products for the insulation of the building structure.

DIN EN 14308-2016建筑設(shè)備和工業(yè)裝置的隔熱保溫產(chǎn)品.硬質(zhì)聚氨酯泡沫及聚異氰脲酸酯產(chǎn)品.規(guī)范.德文版本EN 14308-2015

This European Standard specifies the requirements for factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products, with a closed cell content not less than 90 %, with or without facings, which are used for the thermal insulation of building equipment and industrial installations, with an operating temperature range of approximately, - 200 °C to + 200 °C. Below an operating temperature of - 50 °C, special tests regarding the suitability of the products in the intended application are advised (e. g. liquefaction of oxygen). Manufacturer's advice should be heeded in all cases. The products are manufactured in the form of blocks, faced or unfaced boards, pipe sections, segments and prefabricated ware. This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property that should be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations and invitations to tender. Products with a declared thermal conductivity greater than 0,100 W/(m·K) at 10 °C are not covered by this European Standard. This European Standard does not cover products for in situ-insulation (spraying or dispensing) or products for the insulation of the building structure. This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission index.

DIN EN 14314-2016工業(yè)裝置和建筑設(shè)備用熱絕緣產(chǎn)品.工廠制酚醛泡沫(PF)產(chǎn)品規(guī)格.德文版本EN 14314-2015

This European Standard specifies the requirements for factory made phenolic foam products which are used for the thermal insulation of building equipment and industrial installations with an operating temperature in the range of approximately - 200 °C to + 120 °C. Below an operating temperature of - 50 °C, special tests regarding the suitability of the products in the intended application are advised (e. g. liquefaction of oxygen). Manufacturer's advice should be heeded in all cases. The products are manufactured in the form of blocks, faced or unfaced, boards, pipe sections, segments and prefabricated ware. This European Standard describes product characteristics and includes procedures for testing, evaluation of conformity, marking and labelling. Products covered by this standard are also used in prefabricated thermal insulating systems and composite panels; the performance of systems incorporating these products is not covered. This European Standard does not specify the required level of a given property that should be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application can be found in regulations and invitations to tender. Products with a declared thermal conductivity greater than 0,050 W/(m·K) at 10 °C are not covered by this standard. This European Standard does not cover products for in situ-insulation (blowing or pouring) or products for the insulation of the building structure. This European Standard does not cover the following acoustical aspects: direct airborne sound insulation and impact noise transmission index.

上一篇:塑料管道系統(tǒng) 塑料部件檢測(cè) 下一篇:5G NR基站檢測(cè)
以上是中析研究所金屬面硬質(zhì)酚醛泡沫復(fù)合板檢測(cè)檢測(cè)服務(wù)的相關(guān)介紹,如有其他檢測(cè)需求可咨詢?cè)诰€工程師進(jìn)行了解!

前沿科學(xué)公眾號(hào) 前沿科學(xué) 微信公眾號(hào)
中析抖音 中析研究所 抖音
中析公眾號(hào) 中析研究所 微信公眾號(hào)
中析快手 中析研究所 快手
中析微視頻 中析研究所 微視頻
中析小紅書 中析研究所 小紅書
京ICP備15067471號(hào)-35版權(quán)所有:北京中科光析科學(xué)技術(shù)研究所